SFC Series
The SFC systems are designed for single measurements and can be combined with different sensor measuring and flow block modules. (External) sensors with mA signals can also be connected. Dosing pumps, electric positioners and continuous actuators can be controlled directly according to the measured parameters. As SFC SC and SFC PC the SFC system can deal as signal conditioning unit or as process control unit.
With the DEPOLOX®5 measuring cell the parameters free chlorine, chlorine dioxide, ozone and potassium permanganate are measured. Apart from this additional measuring modules can be used: membrane sensors for free chlorine, total chlorine, chlorine dioxide and ozone as well as “open” sensors for Redox, fluoride, conductivity or pH.
 |
|
 |
| SFC DEPOLOX®5 |
|
SFC VariaSens |
While the flow block module DEPOLOX®5 always containes the DEPOLOX®5 measuring cell, the VariaSens flow block module is designed for using membrane sensors.
The selectable control types offer all possibilities of applications. If three or more parameters are to be measured the MFC system is available.
With an integrated fieldbus module the SFC system can get connected to the well known fieldbus systems PROFIBUS® DP, PROFINET® IO and MODBUS® TCP. For all SFC units except the SFC SC system a CAN sensor/actuator bus interface is available for controlling actuators and evaluating external measurements and module communication.
|